KWX-ATS16A2C19-H3

KWX-ATS16A2C19-H3 19″ rack mountable intelligent automatic transfer switch, 16Amp  (A & B Input plugs ), 2port ( 2 x C19 Output). Provides: Unit Monitoring  and Individual  and Outlet switching On/Off.

KWX-ATS16A2C19-H3- rack mount Automatic Transfer Switch – is a new generation of Intelligent Automatic Transfer Switch. KWX-ATS16A2C19-H3 provides ATS unit monitoring and individual outlet power  switching On/Off.  It offers 2 x C19 outputs connections, combines network power distribution and environmental monitoring technology. It delivers consistent power to single-corded equipment. KWX-ATS16A2C19-H3- has a dual input IEC60309 16A power cords supplying power to the connect load. In the event where the primary power source becomes unavailable, the KWX-ATS16A2C19-H3 will flawlessly source power from the secondary source without interrupting critical loads. The switching occurs safely in just 8ms between the two input sources regardless of their phase. This high-speed transfer rate ensures that the transfer is transparent to the sensitive equipment.

PDU eXperts intelligent KWX-ATS management software enables the administrator to give designated users predetermined control over a range of ATS units or single outlet. Users have the ability to monitor and control directly through the ATS units network module on site, or remotely using our embedded multithreading inner core Real Time Operating Systems (RTOS) software. The management software is accessible within the data centres secure hardwired network, supporting various TCIP/IP protocols, including HTTP, HTTPS, SSL, SNMP versions 1,2 & 3, TELNET, SSH, SMTP and NTP from any network PC or laptop.

Key Features: Adjustable sequential powering (on)-Total current monitoring-Outlets Power Monitoring -Adjustable sequential powering (on)-8 millisecond Switch over-Total current monitoring-Total voltage input & output monitoring-Total kWh used-Power factor recognition-Up to 55°C Hot aisle operating capacity-SMS, SNMP & Email-Effortless user friendly PDU management interface-Control up to 3 KWX slaves from a master  KWX ATS IEC60309 16A Input plugs (A & B) connection-2 x IEC C19 Outlets.

 

Built in environmental monitoring as standard:

Optional:

  • temperature and humidity sensor
  • smoke sensor
  • water logging sensor
  • infrared sensor (Intrusion Detection)
  • rack door sensor

Monitor:

  • total current
  • total kWh
  • input voltage
  • environment humidity
  • environment smoke
  • water logging
  • infrared monitoring
  • door monitoring

Alarm settings:

  • total current threshold alarm
  • temperature and humidity alarm,
  • smoke alarm
  • water logging alarm
  • infrared alarm (intrusion detection)
  • rack door alarm

 

 

Dimensions 440 × 45 × 330 cm